30" Slide-in Range
InstallatIon Manual
sPECIal WaRnInG
InstallatIon anD sERVICE Must BE PERFoRMED BY a QualIFIED InstallER.
IMPoRtant: saVE thIs InstallatIon Manual FoR loCal ElECtRICal
InsPECtoR’s usE.
REaD anD saVE thEsE InstRuCtIons FoR FutuRE REFEREnCE.
ClEaRanCEs & DIMEnsIons
For SAFETY CONSIDERATIONS do not install a appliance in any combustible cabinetry which is not
in accord with the stated clearances and dimensions on page 2. See Figures 1 and 2.
RanGE MEasuREMEnts ......................................2
ClEaRanCEs anD DIMEnsIons..............................2
IMPoRtant notEs.............................................3
unPaCkInG anD ExaMInInG YouR RanGE.................3
IMPoRtant saFEtY InstRuCtIons.........................3
ElECtRICal ConnECtIons ................................ 4-6
MoDEl anD sERIal nuMBER loCatIon ....................4
antI-tIP ..................................................... 6-8
CaRE, ClEanInG anD MaIntEnanCE ......................8
InstallatIon Manual
To reduce the risk of tipping the range, it must
be secured by properly installed Anti-Tip bracket packed with
the range.
IMPoRtant notEs to thE InstallER
•
Read all of the Installation Manual before installing the range.
• Remove all packing material from the oven and drawer before
connecting the electrical supply to the range.
• This range must be electrically grounded in accordance with
local codes, or in their absence, with the National Electrical
Code ANSI/NFPA No. 70—latest edition in United States.
• Observe all governing codes and ordinances.
• Be sure to leave these instructions with the consumer.
• The installation of ranges designed for manufactured (mobile)
home installation must conform with Manufactured Home
Construction and Safety Standard, title 24CFR, part 3280
[Formerly the Federal Standard for Mobile Home Construction
and Safety, title 24, HUD (part 280)] or when such standard
is not applicable, the Standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities
and Setups), ANSI Z225. 1/NFPA 501A- latest edition, or with
local codes in United States.
IMPoRtant notEs to thE ConsuMER
Keep this manual with your Operation Manual for future reference.
• As when using any range generating heat, there are certain
safety precautions you should follow. These are listed in the
Operation Manual. Read all and follow carefully.
• Be sure your range is installed and grounded properly by a
qualified installer or service technician.
• Make sure the wall coverings and the cabinets around the range
can withstand the heat generated by the range.
• Before installing the range in an area covered with
linoleum or any other synthetic floor covering, make sure
the floor covering can withstand heat at least 90˚F (32.2˚C)
above room temperature without shrinking, warping or
discoloring. Do not install the range over carpeting unless
unPaCkInG anD ExaMInInG YouR RanGE
ꢀ Remove all packing
materials from inside
Sealing Surface
theMicrowaveDrawer
and the oven cavity.
1
you place an insulating pad or sheet of /4-inch (0.64cm) thick
plywood between the range and carpeting.
Waveguide
Cover
DO NOT REMOVE
THE WAVEGUIDE
COVER, which is
located on the top
of the Microwave
Drawer.
Never leave children alone or unattended in the
area where an a range is in use. As children grow, teach them the
proper, safe use of all appliances.
Sealing Surface
ꢁ Remove the feature
sticker, if there is one.
Check the drawer for
any damage, such as
misaligned or bent
Microwave
Drawer Cavity
Stepping, leaning or sitting on the door or drawer
of this range can result in serious injuries and can also cause damage
to the range.
drawer, damaged drawer seals and sealing surfaces, broken
or loose drawer guides and dents inside the drawer or on the
front side of the drawer. If there is any damage, do not operate
the Microwave Drawer and contact your dealer or a SHARP
AUTHORIZED SERVICER.
• Do not store items of interest to children in the cabinets
above the range. Children could be seriously burned climbing
on the range to reach items.
• To eliminate the need to reach over the cooktop, cabinet storage
space above the cooktop should be avoided.
• Do not use the oven as a storage space. This creates a
potentially hazardous situation.
IMPoRtant saFEtY InstRuCtIons
If the information in this manual is not followed
exactly, a fire or electrical shock may result causing property damage,
personal injury or death.
• Never use the range for warming or heating the room.
• Do not store or use gasoline or other flammable vapors and
liquids near this or any other range. Explosions or fires could
result.
• all ranges Can tIp
• Reset all controls to the “off” position after using a
programmable timing operation.
• Injury to persons Could result
When usIng the selF-Clean Feature:
• Install antI-tIp braCket paCked
WIth range
• Remove broiler pan, oven racks, food and other utensils
before self-cleaning the oven. Wipe up excess spillage. Follow
the precleaning instructions in the Operation Manual.
• see antI-tIp braCket teMplate
For InstallatIon InstruCtIons
ꢂ
InstallatIon Manual
208/240 Volt ConneCtIon InstruCtIons
ElECtRICal ConnECtIons
The installer or consumer is responsible for connecting the power
supply cord to the connection block located behind the back panel
access cover.
The range can be set for 208V or 240V. The voltage setting for your
range is pre-set at 240V from the factory. Follow these steps to
change the voltage setting.
ꢀ Locate the voltage switch on the lower back side of the range.
ꢁ Remove the screw and rotate the switch plate 180˚ as indicated
in the Figure 4.
This range may be connected by means of permanent “hard wiring”
(flexible armored or nonmetallic shielded copper or aluminum cable),
or by means of a power supply cord kit. Only a power supply cord kit
rated at 240 volts or 208 volts and 50 amperes and marked for use
with ranges shall be used. Cord must have either 3 or 4 conductors
to match electric receptacle. The power cord kit is not included so
must be purchased at an appliance store.
ꢂ Reinsert the switch plate and replace screw as indicated
in Figure 5. The voltage setting is indicated by the visible
marking.
screw
180˚
For mobile homes, new installations, recreational vehicles or areas
where local codes do not permit grounding through neutral, a 4 con-
ductor power supply cord kit rated at 240 volts or 208 volts minimum,
50 amperes and marked for use with ranges should be used.
screw
Terminals on end of wires must be either closed loop or open-end
spade lugs with upturned ends. Cord must have strain-relief clamp.
3
The range connection opening should be 1 /8-inches.
Risk of fire or electrical shock exists if an
incorrect size range cord kit is used, the installation instructions
are not followed precisely or a strain relief clamp is not used.
Figure 4
Figure 5
3 & 4-WIre eleCtrICal Wall reCeptaCle types &
reCoMMended MountIng orIentatIon on Wall
Do not loosen the nuts which secure the factory-
installed range wiring to the terminal block while connecting
range. Electrical failure or loss of electrical connection may
occur.
Figure 6A illustrates 4-wire receptacle required for new and
remodeled installations.
Figure 6B illustrates 3-wire receptacle that is allowed for existing
installations.
eleCtrICal shoCk hazard
• DISCONNECT POWER TO THE CIRCUIT BREAKER
OR FUSE BOX BEFORE MAKING THE ELECTRICAL
CONNECTION.
• Electrical ground is required on this range.
• Donotconnecttotheelectricalsupplyuntil rangeispermanently
grounded.
• This range must be connected to a grounded, metallic,
permanent electrical system or the grounding connector of the
power cord should be connected to the grounding terminal or
wire lead on the range.
4-wire wall receptacle (14-50R)
3-wire wall receptacle (10-50R)
Figure 6a
Figure 6b
aCCess to terMInal bloCk
• Failure to heed these warnings could result in a fire, personal
injury or electrical shock.
Loosen screw on rear access cover and pull down as illustrated in
Figure 7 to access terminal block wiring connection.
strain relief clamp
screw
Rating plate
Model and serIal nuMber loCatIon
The rating plate, including model and serial number, is located on
the faceplate behind the Microwave Drawer front.
Figure 7
Figure 8
ꢃ
InstallatIon Manual
center, lowest screw. See Figure 10. The ground strap must
not be removed unless National, State or Local Codes do not
permit use of a ground strap.
PoWER CoRD ConnECtIons
4-WIre ConneCtIon InstruCtIons
note:
If the ground strap is removed for any reason, a
Before wiring the range, review the suggested power source location
drawing in Figure 2. If connecting to a 4-wire electrical system for a
new branch-circuit or mobile home use a 4-wire connection.
separate ground wire must be connected to the separate ground
screw attached to the range chassis and to an adequate ground
source.
ꢀ Follow the power supply cord kit manufacturer’s Installation
Instructions and install the strain relief clamp on the cord. See
Figure 8.
ꢃ
Make sure all connections are tightened securely and replace
the rear access cover and secure with screw. See Figure 7.
ꢁ Connect the end connectors for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 9.
3 & 4-WIre perManent WIre ConneCtIons
3–wire permanent connection – follow steps 1, 2 and 5 below.
4–wire permanent connection – follow all steps below.
IMportant
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
Before wiring the range, review the suggested power source location
drawings in Figure 2. If connecting to a 4-wire electrical system:
ꢀ Follow the manufacturer’s Installation Instructions for installing
the strain relief clamp.
ꢂ You must disconnect the ground strap. Remove the factory
installed ground screw and plate to release the copper ground
strap from the frame of the range. Cut and discard the copper
ground strap and plate. KEEP the ground screw. See Figure 9.
ꢁ Strip insulation away from the ends of the permanent wiring
for line 1, line 2 and neutral; also strip ground wire on 4-wire
connections. Tighten all 3 or 4-wire leads to the terminal block.
Follow wire locations shown in Figure 11.
ꢃ Connect the green ground wire lead with the eyelet to the frame
of the range with the ground screw using the same hole in the
frame where the ground screw was originally installed. See
Figure 9.
IMportant
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
ꢄ Make sure all screws are tightened securely and replace the
rear access cover and secure with screw. See Figure 7.
note:
For 3-wire permanent connection skip steps 3 and 4
and continue with step 5.
3-WIre ConneCtIon InstruCtIons
ꢂ Disconnect the ground strap. Remove the factory installed
ground screw and plate to release the factory installed copper
ground strap from frame of the range. Cut and discard the
copper strap from the terminal block. KEEP the ground screw,
ground plate and go to step 4.
For existing installations ONLY, refer to Figure 10.
ꢀ Follow the power supply cord kit manufacturer’s Installation
Instructions and install the strain relief clamp. See Figure 10.
ꢁ Connect the end connectors for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 10.
ꢃ Connect the green ground wire lead to the frame of the range
using the ground screw and plate as shown in Figure 12. Be sure
to install using the same hole in the frame where the ground
screw was originally installed.
IMportant
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
ꢄ Make sure all connections are tightened securely and replace
the rear access cover. See Figure 7.
ꢂ A ground strap is installed on this range which connects the
center terminal of the neutral terminal block to the range
chassis. The ground strap is connected to the range by the
note:
Non-terminated field wire compression connections
must be set at approximately 90 in./lb.
4-WIre ConneCtIon
ꢂ-WIre ConneCtIon
Note: Install strain
relief clamp. Center
or white wire must
always be attached to
Connect
Terminal block
the center terminal on
line 1 here.
Connect line
1 here.
block.
Connect line 2 here.
Terminal block
Cut ground strap.
Discard ground
strap and ground
plate.
Connect neutral
here.
Ground strap
Connect line 2 here.
Note: Install strain
relief clamp. Center
must always be
attached to the
center terminal on
block.
Connect neutral
(white or center) here.
A user supplied
strain relief clamp
must be installed
at this location. It
Connect green
A user supplied strain
relief clamp must be
installed at this
insulated copper
ground wire with
ground screw here.
3
requires 1 /8"
location. It requires 1
(3.5 cm) diameter
cord kit hole.
3
/8" (3.5 cm) diameter
cord kit hole.
Figure 9
Figure 10
ꢄ
|